ProT Ar-Ge FADOS7F1 Fault Detector and Oscilloscope, 10 V

(No reviews yet) Write a Review
SKU:
FADOS7F1-10V
MPN:
FADOS7F1 10V
Availability:
This product usually ships within 5 to 10 business days
Shipping:
Calculated at Checkout
  • ProT Ar-Ge FADOS7F1 Fault Detector and Oscilloscope, 10 V
  • ProT Ar-Ge FADOS7F1 Fault Detector and Oscilloscope, 10 V
  • ProT Ar-Ge FADOS7F1 Fault Detector and Oscilloscope, 10 V
$2,084.00

Description

Prot Ar-Ge Circuit Board Testers

ProT Ar-Ge FADOS7F1 FAULT DETECTOR & OSCILLOSCOPE, 10 V

Product Part Number: FADOS7F1-10V

ProT Ar-Ge FADOS7F1 10V Fault Detector and Oscilloscope is designed to trouble shoot all types of electronic boards. FADOS7F1 is operated by a "VI Test Voltage - Control Analysis" PC software.

Signature Analysis is a power-off test method that is used to troubleshoot circuit boards. FADOS7F1 works by applying a current-limited sine wave through a serial resistor point of touched on circuit and Voltage-Current (Signature) graph is displayed on the computer screen. In addition to these features, the computer software analyzes the Voltage – Current graph and shows the equivalent circuit diagram and the electronic components of the contact point. Those features are intended to provide guidance to the user in order to facilitate trouble shooting.

Prot Ar-Ge Circuit Board Testers

PRIMARY FEATURES

  1. Dual - Channel Fault Detection by V / T tester (Analog Signature Analyzer - Trouble Shooting)
    Fault detection by direct comparison of the current-voltage characteristics (signatures) of a working and a faulty circuit board without applying power to the unit under test.
  2. Fault Detection by Comparison with Stored Signatures (Memory)
    Signatures of a functioning board can be saved and used at a later time as a reference for troubleshooting a faulty board. The point to touch can be indicated by a cross hair mark at an image of the board.
  3. Equivalent Circuit Diagram
    Display of an equivalent circuit that corresponds to the characteristic on the touched point.
  4. Display Values of Resistor, Capacitor and Diode Threshold
    Display the calculated values of resistance, capacitors and diode threshold voltages corresponding to the conditions at the contacted node.
  5. Dual - Channel Digital PC Oscilloscope
    As occasion may require, device can be used as oscilloscope.
  6. 0.2... 25KHz Square Wave Signal Output
    Channel 2 is used as a square wave generator. Channel 1 can be used as an oscilloscope.
  7. Analogue Voltage Output (2,5 mV Sensitivity)
    Channel 2 is used as Analog DC output -10 V +10 V. Channel 1 can be used as an oscilloscope.

PCB Fault Finding Technique

Usage of FADOS7F1: Determining faults of all types of electronic cards such as electronic cards of medical devices, textile and any other machines; automobile electronics; computer, monitor, TV, etc.

Electronic Components Test: IC, transistor, FET, IGBT, resistor, capacitor, indicator, ect. This device is used to determine the faults at all these electronic components.

Usage: FADOS7F1 is a double-channel VI tester. While using TEST feature, comparison can be applied without giving energy to card; while using OSCILLOSCOPE feature, energy is given to card and signals are controlled.

Usage1: One of the channels is connected to the chassis of the solid card, other channel is connected to the chassis of faulty card. Same points are touched by both channels. Cards are compared by touching probes to the same points of both cards. If both VI graphics are the same, touched points are solid. If not, VI graphs do not collide one another, and this means the faulty point is found.

Usage2: Different points of solid card can be recorded to memory. These recorded data is, then, opened and used in order to determine the faults on faulty card.

Usage3: Without solid card or recorded data, faulty components can be found by looking at the VI Graph. All components have different graphs; having some experience, user will find the faults just by looking at graphs without comparison.

Prot Ar-Ge Circuit Board VI Testing Screen

Prot Ar-Ge Oscilloscope Screen

What's In The Box

  • FADOS7F1-10V Fault Detector & Oscilloscope (1)
  • Oscilloscope Probe Tips (2)
  • Ground (COM) Cable (1)
  • USB Cable (1)
  • User Manual and Installation Software CD-ROM (1)
  • Handbag (1)

SPECIFICATIONS

Prot Ar-Ge Circuit Board Testers

FADOS SERIES SPECIFICATIONS MATRIX

FAULT DETECTION (VI Tester) FEATURES FADOS7F1 10V FADOS7F1 18V FADOS9F1
Voltage Steps & Values: 4 Voltage Steps: ±1V, ±2V, ±5V, ±10V 5 Voltage Steps: ±1V, ±2V, ±6V, ±12V, ±18V 5 Voltage Steps: ±1V, ±3V, ±6V, ±12V, ±24V
Resistance Steps & Values: 3 Resistance Steps: Current Level
Low: 47 KΩ, Medium: 2.6 KΩ, High: 385 Ω
4 Resistance Steps: Current Level
Low: 47 KΩ, Med1: 3.5 KΩ, Med2: 700 Ω, High: 250 Ω, High: (For μF Inductors and works at ±3V ) 22 Ω
Frequency Steps & Values: For ±5 Voltage Frequency Values
Very Low Frq.: 2.71 Hz
Low2 Frq.: 3.43 Hz
Low1 Frq.: 10.28 Hz
Test Frq.: 27.41 Hz
High Frq.: 781,2 Hz
For ±6 Voltage Frequency Values
Very Low Frq.: 2.71 Hz
Low2 Frq.: 5.71 Hz
Low1 Frq.: 17.13 Hz
Test Frq.: 45.68 Hz
High Frq.: 781,2 Hz
(Note: High Frq. is for only ±12V)
For ±6 Voltage Frequency Values
Very Low Frq.: 2.16 Hz
Low2 Frq.: 6.85 Hz
Low1 Frq.: 20.56 Hz
Test Frq.: 54.82 Hz
High Frq.: 2,232 KHz
(Note: High Frq. is for only ±3V and for measuring pF capacitors or μF Inductors.)
Number of Channels: 2 Channels
Sccan Modes: Manual or Automatic. Automatic selection steps of voltage, current, frequency
Memory Function: Fault detection by comparison with the stored signatures. Recording data with image. Yes Yes Yes
Equivalent circuit diagram Yes Yes Yes
Resistor, capacitor, diode, etc. measurement values Yes Yes Yes
Inductor masurement values No No Yes
Simultaneous screening of 3 adjustment graphs Yes Yes Yes
Varied audio notification at compatible and incompatible points Yes Yes Yes
POWER–IR TEMPERATURE FEATURES FADOS7F1 10V FADOS7F1 18V FADOS9F1
Programmable Integrated DC Power Supply: No No The output voltage is adjustable. 0 to 16 volts with an output current 0 to 1500 mA
Non-touched IR Temperature Probe: No No The output voltage is adjustable. 0 to 16 volts with an output current 0 to 1500 mA
PC OSCILLOSCOPE FEATURES FADOS7F1 10V FADOS7F1 18V FADOS9F1
Input Voltage: Probe 1X: ±5 V, 10X: ±50 V Probe 1X: ±9 V, 10X: ±50 V Probe 1X: ±10 V, 10X: ±50 V
DIGITAL ANS ANALOG OUTPUT FADOS7F1 10V FADOS7F1 18V FADOS9F1
Outut Voltage: -5V to +5V -9V to +9V -12V to +12V
View AllClose