ProT Ar-Ge FADOS9F1 Fault Detector and Oscilloscope

(No reviews yet) Write a Review
SKU:
FADOS9F1
MPN:
FADOS9F1
Availability:
This product usually ships within 5 to 10 business days
Shipping:
Calculated at Checkout
  • ProT Ar-Ge FADOS9F1 Fault Detector and Oscilloscope
  • ProT Ar-Ge FADOS9F1 Fault Detector and Oscilloscope
  • ProT Ar-Ge FADOS9F1 Fault Detector and Oscilloscope
  • ProT Ar-Ge FADOS9F1 Fault Detector and Oscilloscope
$3,232.00

Description

Prot Ar-Ge Circuit Board Testers

ProT Ar-Ge FADOS9F1 FAULT DETECTOR & OSCILLOSCOPE

Product Part Number: FADOS9F1

ProT Ar-Ge FADOS9F1 Fault Detector and Oscilloscope is designed to trouble shoot all types of electronic boards. FADOS9F1 is operated by a "VI Test Voltage - Control Analysis" PC software.

Signature Analysis is a power-off test method that is used to troubleshoot circuit boards. FADOS9F1 works by applying a current-limited sine wave through a serial resistor point of touched on circuit and Voltage-Current (Signature) graph is displayed on the computer screen. In addition to these features, the computer software analyzes the Voltage – Current graph and shows the equivalent circuit diagram and the electronic components of the contact point. Those features are intended to provide guidance to the user in order to facilitate trouble shooting.

Prot Ar-Ge Circuit Board Testers

PRIMARY FEATURES

  1. Dual - Channel Fault Detection by V / T tester (Analog Signature Analyzer - Trouble Shooting)
    Fault detection by direct comparison of the current-voltage characteristics (signatures) of a working and a faulty circuit board without applying power to the unit under test.
  2. Fault Detection by Comparison with Stored Signatures (Memory)
    Signatures of a functioning board can be saved and used at a later time as a reference for troubleshooting a faulty board. The point to touch can be indicated by a cross hair mark at an image of the board.
  3. Equivalent Circuit Diagram
    Display of an equivalent circuit that corresponds to the characteristic on the touched point.
  4. Display Values of Resistor, Capacitor and Diode Threshold
    Display the calculated values of resistance, capacitors and diode threshold voltages corresponding to the conditions at the contacted node.
  5. Dual - Channel Digital PC Oscilloscope
    As occasion may require, device can be used as oscilloscope.
  6. 0.2... 25KHz Square Wave Signal Output
    Channel 2 is used as a square wave generator. Channel 1 can be used as an oscilloscope.
  7. Analogue Voltage Output (2,5 mV Sensitivity)
    Channel 2 is used as Analog DC output -10 V +10 V. Channel 1 can be used as an oscilloscope.
  8. Programmable Integrated DC Power Supply for Creating Power DC VI Graph
    The output voltage is adjustable. 0 to 16 volts with an output current 20 to 1500 mA, for giving energy to circuit board and creating Power DC Voltage-Current Graph.
  9. Non Touched IR Temperature Sensor
    To detect more heated components and draw a heat map of the circuit board.

Comparison to FADOS7F1

Two unique features are added to the FADOS9F1 over the FADOS71. First feature is the Programmable DC Power Supply; It can be adjusted between 0-16V and 20-1500mA with power output; the DC Voltage/Current graphs of the electronic card power supply can be produced. The second feature is the “IR Remote Temperature Measurement Sensor”; this sensor is used to find the components that heat up by drawing too much current. Using these two features together may reduce the time for trouble shooting some malfunctions by 5 to 10 times. These features can be used as a new technique for trouble shooting.

In this technique, power cable is connected the input of intact board and maximum voltage is adjusted. By pushing the “Power Test” button, the voltage is adjusted from “0” to the desired voltage in 100 mV increments and the voltage-current graph is obtained, which can be recorded when needed. After waiting a few minutes, the temperature map can be obtained by measuring the temperature of the components with the IR sensor.

Then the graph for the intact card is called for testing the defective boards. The maximum current is determined and the supply graph for the defective card is produced. If the defective card draws more current, the temperature of the materials is checked with the IR sensor, allowing to find the material drawing too much current. If the defective card draws less current, this might suggest an open circuit in the supply line. In such a case, the oscilloscope screen is activated to find the areas, where no power is received and to find the broken connection in the line easily. If the defective board produces the same power graph as the intact board, then the VI Tester is activated to find the malfunction.

The FADOS9F1 may be used for Microvolt measurements as well and an output port is provided for attaching a multiplexer. The FADOS products are designed for multiple functions considering all the situations the customer might encounter.

Prot Ar-Ge Circuit Board IR Testing Screen

Prot Ar-Ge Cable set

What's In The Box

  • FADOS9F1 Fault Detector & Oscilloscope (1)
  • Oscilloscope Probe Tips (2)
  • USB Cable (1)
  • IR Temperature Sensor (1)
  • Power cable with alligator clips (1)
  • Power Adapter, 19V, 3.9A (1)
  • Installation Software CD-ROM (1)
  • Handbag (1)

DOCUMENTATION

SPECIFICATIONS

Prot Ar-Ge Circuit Board Testers

FADOS SERIES SPECIFICATIONS MATRIX

FAULT DETECTION (VI Tester) FEATURES FADOS7F1 10V FADOS7F1 18V FADOS9F1
Voltage Steps & Values: 4 Voltage Steps: ±1V, ±2V, ±5V, ±10V 5 Voltage Steps: ±1V, ±2V, ±6V, ±12V, ±18V 5 Voltage Steps: ±1V, ±3V, ±6V, ±12V, ±24V
Resistance Steps & Values: 3 Resistance Steps: Current Level
Low: 47 KΩ, Medium: 2.6 KΩ, High: 385 Ω
4 Resistance Steps: Current Level
Low: 47 KΩ, Med1: 3.5 KΩ, Med2: 700 Ω, High: 250 Ω, High: (For μF Inductors and works at ±3V ) 22 Ω
Frequency Steps & Values: For ±5 Voltage Frequency Values
Very Low Frq.: 2.71 Hz
Low2 Frq.: 3.43 Hz
Low1 Frq.: 10.28 Hz
Test Frq.: 27.41 Hz
High Frq.: 781,2 Hz
For ±6 Voltage Frequency Values
Very Low Frq.: 2.71 Hz
Low2 Frq.: 5.71 Hz
Low1 Frq.: 17.13 Hz
Test Frq.: 45.68 Hz
High Frq.: 781,2 Hz
(Note: High Frq. is for only ±12V)
For ±6 Voltage Frequency Values
Very Low Frq.: 2.16 Hz
Low2 Frq.: 6.85 Hz
Low1 Frq.: 20.56 Hz
Test Frq.: 54.82 Hz
High Frq.: 2,232 KHz
(Note: High Frq. is for only ±3V and for measuring pF capacitors or μF Inductors.)
Number of Channels: 2 Channels
Sccan Modes: Manual or Automatic. Automatic selection steps of voltage, current, frequency
Memory Function: Fault detection by comparison with the stored signatures. Recording data with image. Yes Yes Yes
Equivalent circuit diagram Yes Yes Yes
Resistor, capacitor, diode, etc. measurement values Yes Yes Yes
Inductor masurement values No No Yes
Simultaneous screening of 3 adjustment graphs Yes Yes Yes
Varied audio notification at compatible and incompatible points Yes Yes Yes
POWER–IR TEMPERATURE FEATURES FADOS7F1 10V FADOS7F1 18V FADOS9F1
Programmable Integrated DC Power Supply: No No The output voltage is adjustable. 0 to 16 volts with an output current 0 to 1500 mA
Non-touched IR Temperature Probe: No No The output voltage is adjustable. 0 to 16 volts with an output current 0 to 1500 mA
PC OSCILLOSCOPE FEATURES FADOS7F1 10V FADOS7F1 18V FADOS9F1
Input Voltage: Probe 1X: ±5 V, 10X: ±50 V Probe 1X: ±9 V, 10X: ±50 V Probe 1X: ±10 V, 10X: ±50 V
DIGITAL ANS ANALOG OUTPUT FADOS7F1 10V FADOS7F1 18V FADOS9F1
Outut Voltage: -5V to +5V -9V to +9V -12V to +12V
View AllClose